Rectifier — DHT — B4
···
+ Compare
RCA
↗ Radiomuseum
Known Equivalents & Substitutes
No known equivalents. If you know of any, use the ⚑ Report Issue button above.
Similar Tubes (Not Drop-In Compatible)
866A
Another mercury-vapor half-wave rectifier — different ratings and base
Electrical Specifications
Rectifier
Peak Inverse Voltage
Peak Inverse Voltage (max)
10,000
V
Voltage Drop (typical)
Tube Voltage Drop (approx.)
10
V
DC Output Current (max)
Average Anode Current (max)
1,750
mA
other
Peak Anode Current (max)
Peak Anode Current (max)
7,000
mA
Heater
Heater Voltage
Filament Voltage
5
V
Heater Current
Filament Current
10
A
Notes
Mercury-vapor rectifier — requires a 30-second minimum warm-up at rated filament voltage before applying anode voltage.
Condensed-mercury temperature must be maintained between 20-60°C (or 20-50°C for reduced ratings). External heating or cooling may be required.
Peak inverse voltage rating is 10,000 V (20-60°C range) or 15,000 V (20-50°C range).
Tube voltage drop approximately 10 V.
Used in half-wave, full-wave, and polyphase rectifier circuits for transmitter power supplies.
Pin Layout — B4
1
2
3
4
1
No Connection
2
Filament
,
Cathode
3
Filament
4
No Connection
TC
References
https://frank.pocnet.net/sheets/049/6/673.pdf
Top Cap —
Anode (top cap)